Skip to main content

File #: 25-P&Z-252    Version: 1
Type: Preliminary Plats and Replats Status: Agenda Ready
File created: 9/9/2025 In control: Planning & Zoning Commission
On agenda: 9/18/2025 Final action:
Title: Preliminary consideration of the replat of Lot 1, Block 2, Villas San Agustin, Unit 1 into Bridge Crossing Villas (PUD). The intent is residential. PL-197-2025 District VII - Cm. Vanessa Perez
Sponsors: Planning & Zoning Commission
Attachments: 1. Front-of-Lot Utilities Letter, 2. Aerial Location Map, 3. Plat Notes, 4. Plat Exhibit
Date Ver.Action ByActionResultAction DetailsMeeting DetailsVideo
No records to display.

SUBJECT

title

Preliminary consideration of the replat of Lot 1, Block 2, Villas San Agustin, Unit 1 into Bridge Crossing Villas (PUD). The intent is residential.

PL-197-2025
District VII - Cm. Vanessa Perez

body

PREVIOUS COUNCIL ACTION

N/A

 

BACKGROUND

APPLICANT: Ariva, LTD
ENGINEER: Peua Consulting, LLC

SITE: This 12.56-acre tract of land is located on the corner of Frontage Road and Atlanta Drive. The zoning for this 162-lot development is B-3 PUD (Community Business District - Planned Unit Development). This tract is located in District VII - Cm. Vanessa Perez.

COMMITTEE RECOMMENDATION

N/A

 

STAFF RECOMMENDATION

recommendation

APPROVE SUBJECT TO THE FOLLOWING COMMENTS:

Planning:

1. Provide a plat note, stating the purpose of this re-plat.

 

2. Provide a plat note referencing the approved PUD Ordinance, including the ordinance number and approval date.

 

3. Clarify and label the purpose of Lot 1, Block 5.

 

4. Label Pedestrian Walkways.

 

 

5. Provide the legal description (field notes) of the tract.

 

 

6. Provide the proposed street names.

 

7. Define S.D.E.

 

8. Coordinate with the Parks Department for the parkland dedication.

 

9. Access to Bob Bullock Loop (Loop 20) is subject to the review and approval by Texas Department of Transportation (TX-DOT).

 

10. The developer has submitted a notice of intention to place utilities in the front of the lot. The front-of-lot utility layout/schematics, as prepared by the Developer’s engineer, shall be submitted to plan review (Section 3-4 B.2 - Subdivision Ordinance).

 

11. Identify all easements.

 

12. All improvements as per the Subdivision Ordinance.

 

 

Fire:

1. Fire Hydrants Required every 500ft for Residential development. (Ordinance 2012-O-183, IFC 2012 Section 507.5.1, where required. Fire Hydrants shall be required along public and private streets at every 500 feet for residential development.)

 

2. Remoteness - where two fire apparatus - access roads are required, they shall be placed a distance apart equal to not less than one-half of the length of the maximum overall diagonal dimension of the lot or area to be served.

 

Traffic Safety: No comments submitted.
Engineering: No comments submitted.
Environmental: No comments submitted.

Parks & Leisure: No comments submitted.
Water & Utilities: No comments submitted.
WEBB County App: No comments submitted.
AEP Engineers: No comments submitted.
U.I.S.D.: No comments submitted.
L.I.S.D.: No comments submitted.
AT&T: No comments submitted.

NOTICE TO THE DEVELOPER:
Planning:
1. Only the utility easements within the plat boundaries are subject to change prior to plat recordation due to revisions by the utility companies.
2. All comments set forth are preliminary comments and not an exhaustive list. Additional comments may be added prior to final plat approval.
end