Legislation Details

File #: 25-P&Z-265    Version: 1
Type: Preliminary Plats and Replats Status: Agenda Ready
File created: 9/24/2025 In control: Planning & Zoning Commission
On agenda: 10/2/2025 Final action:
Title: Preliminary consideration of the plat of Ponderosa Commercial Subdivision, Unit 3A. The intent is commercial. PL-208-2025 District IV - Cm. Ricardo "Rick" Garza
Sponsors: Planning & Zoning Commission
Attachments: 1. Aerial Location Map, 2. Plat Notes, 3. Plat Exhibit
Date Ver.Action ByActionResultAction DetailsMeeting DetailsVideo
No records to display.

SUBJECT

title

Preliminary consideration of the plat of Ponderosa Commercial Subdivision, Unit 3A. The intent is commercial.

PL-208-2025
District IV - Cm. Ricardo “Rick” Garza

body

 

PREVIOUS COUNCIL ACTION

N/A

 

BACKGROUND

APPLICANT: Killam Development, LTD / Killam Ranch Properties, LTD
ENGINEER: Mesquite Engineering

SITE: This 45.2819-acre tract of land is located south of E. Saunders St. and west of Bob Bullock Loop (Loop 20). The zoning for this 18-lot development is B-4 (Highway Commercial District). This tract is located in District IV - Cm. Ricardo “Rick” Garza

 

COMMITTEE RECOMMENDATION

N/A

 

STAFF RECOMMENDATION

recommendation

APPROVE SUBJECT TO THE FOLLOWING COMMENTS:

Planning:

 

1. Based on the configuration of this plat, the internal lots will obtain primary access through the proposed 40-foot access easement (shaded in grey) that connects to Loop 20 at multiple points. Revise the easement from 40 feet to 50 feet in width, with a 30-foot paving section, in accordance with Section 3-2 (A) of the Subdivision Ordinance. This primary access easement is intended to provide adequate capacity and safe circulation for traffic generated by this development, ensuring access to each proposed lot that does not have access to a public roadway.

 

2. Ensure the plat boundary matches the recorded boundaries of Lot 1, Block 1, Ponderosa Commercial, Unit 3. The current boundary does not align with the recorded plat (Vol. 39, Pg. 81, Webb County Plat Records).

 

3. Clearly delineate the limits of Lot 5, Block 1, so as not to create confusion with the internal access easement.

 

4. Revise the Ponderosa Masterplan to reflect the configurations shown on this plat.

 

5. Revise the City Engineer as “Eliud De Los Santos, P.E.” on the Plat Approval certificate block.

 

6. Access to Bob Bullock Loop (Loop 20) is subject to the review and approval by Texas Department of Transportation (TX-DOT).

 

7. Identify all easements.

 

8. All improvements as per the Subdivision Ordinance.

 

Fire:

 

1. Fire Hydrants are required every 300ft for commercial development (Ordinance 2012-O-183, IFC 2018 Section 507.5., where required Fire Hydrants shall be required along public and private streets at every 300 feet for commercial development.

 

2. Dead End fire apparatus access in excess of 150 feet will be provided with width and turnaround Provisions with Table D103.4 (120-foot hammer head, 60-foot Y, 96-foot cul-de-sac).

 

 

Traffic Safety: No comments submitted.
Engineering: No comments submitted.
Environmental: No comments submitted.

Parks & Leisure: No comments submitted.
Water & Utilities: No comments submitted.
WEBB County App: No comments submitted.
AEP Engineers: No comments submitted.
U.I.S.D.: No comments submitted.
L.I.S.D.: No comments submitted.
AT&T: No comments submitted.

NOTICE TO THE DEVELOPER:
Planning:
1. Only the utility easements within the plat boundaries are subject to change prior to plat recordation due to revisions by the utility companies.
2. All comments set forth are preliminary comments and not an exhaustive list. Additional comments may be added prior to final plat approval.

end